Gravity ↔ Qwiic compatibility
Connecting Gravity and Qwiic — and the reverse, Qwiic to Gravity. Here's the verdict, the exact part, and the voltage catch.
Gravity uses a 4-pin plug, but its power and ground sit in different positions than the other ecosystems. Plugging in blind can reverse power. Use a proper adapter and verify pin order before applying power. Qwiic is 3.3 V only — if your host runs 5 V logic, add a level shifter or you may damage it.
Side by side
| Spec | Gravity | Qwiic |
|---|---|---|
| Connector | Gravity 4-pin | JST-SH |
| Pitch | 2 mm | 1 mm |
| Logic | varies | 3v3 |
Why this verdict
What actually decides Gravity ↔ Qwiic
The connector. Gravity uses a Gravity 4-pin at 2 mm; Qwiic uses a JST-SH at 1 mm. Different housings and different pitch mean no cable mates them directly — an adapter is doing real work, not just convenience.
The pin order. Gravity runs VCC → GND → SCL → SDA while Qwiic runs GND → 3V3 → SDA → SCL. A plug that fits mechanically but disagrees on order is the worst case: it looks right and the bus stays silent, or worse, power meets a data line. Use an adapter made for this pair — see the pinout visualizer to see the two side by side.
The voltage. Gravity is varies; Qwiic is 3.3 V only. i2c has no negotiation — whatever the host drives lands on every device. If one side is 3.3 V-only and your host is 5 V, a level shifter isn't optional, it's the difference between a working bus and a dead sensor. The compatibility checker surfaces this for any combination.
Bridged, it's still one ordinary i2c bus: unique addresses per device (conflicts have fixes), pull-ups in parallel, and a 400 pF capacitance budget. Nothing answering after you connect? Run an i2c scan — it separates a cable problem from an address problem in seconds.
Questions
Gravity & Qwiic FAQ
Can you connect Gravity to Qwiic directly?
Not directly — Gravity (Gravity 4-pin) and Qwiic (JST-SH) use different connectors, so you need an adapter. Gravity uses a 4-pin plug, but its power and ground sit in different positions than the other ecosystems. Plugging in blind can reverse power. Use a proper adapter and verify pin order before applying power. Qwiic is 3.3 V only — if your host runs 5 V logic, add a level shifter or you may damage it.
Do I need a level shifter between Gravity and Qwiic?
Only if the logic voltages differ — typically a 5 V host with a 3.3 V-only device. Gravity is varies; Qwiic is 3v3. If both ends run at 3.3 V, no level shifter is needed.
Is the Gravity pinout the same as Qwiic?
No. Gravity is wired VCC / GND / SCL / SDA and Qwiic is GND / 3V3 / SDA / SCL. That difference is exactly why you can't just force a plug that seems to fit — an adapter built for this pairing re-orders the conductors for you.
Can I chain Gravity and Qwiic devices on one bus?
Physically yes, once the connectors are bridged — electrically it's still one i2c bus, so the usual rules decide it. Every device needs a unique address, all the pull-up resistors sit in parallel, and total cable capacitance has a 400 pF ceiling. Mixing ecosystems doesn't change the bus; it just changes the plug.
Related pairings
Other Gravity and Qwiic combinations
Every pairing is pre-answered — here are the rest involving either of these two. The verdict on each tile is the cautious one, since it assumes nothing about your host's voltage.
Or start from a standard: Gravity and Qwiic each list their pinout and every ecosystem they reach. The full pairing index has all 15, and the compatibility checker does it interactively.